Flowserve NRGT26-1 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
12
A
Thermal insulation provided on site, d = 20 mm (without thermal insulation of steam boiler)
B Seating surface
C Joint ring (of stainless steel 1.4301) D 27 x 32 to DIN 7603
D Electrode thread ¾" BSP, DIN ISO 228-1
E Flange DN 50 (2"), PN 40 to DIN 2635
F Protection tube
G Spacer disc
H Housing screws M4
I Cable entry M20 x 1.5
J Housing cover
K Measuring range switch
L Potentiometer for lower measuring point (4 mA)
M LED “Level 0 %”
N LED “Level > 0 %, <100 %”
O LED “Level 100 %”
P Potentiometer for upper measuring point (20 mA)
Q Terminal lugs for voltage measurement (between 0-7 V DC, level proportional)
R Thermal fuse T
max
102 °C
S Terminal strip
T PE connection
U Plug
Key
1 NRGT 26-1: Max. length of installation at 238 °C
2 NRGT 26-1: Measuring range
3 NRGT 26-1S: Max. length of installation at 238 °C
4 NRGT 26-1S: Measuring range
Design / Functional Elements