Flowserve PA46 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Flowserve PA46 herunter. Flowserve PA46 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
GESTRA Steam Systems
PA 46
PA 47
MPA 46
MPA 47
Installation Instructions 81844700
RapidAction Intermittent Valve for Removing Boiler Sludge
PA 46, PA 47, MPA 46, MPA 47
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - GESTRA Steam Systems

1GESTRA Steam SystemsPA 46PA 47MPA 46MPA 47Installation Instructions 81844700RapidAction Intermittent Valve for Removing Boiler Sludge PA 46, PA 47

Seite 2 - Contents

10Fig. 1Technical Data  continued Capacity chart PA 46, PA 47, MPA 46, MPA 47Calculation of the amount of boiler water to be discharged according to

Seite 3 - Contents  continued 

11Fig. 2Technical Data  continued Control pressure chart MPA 46, MPA 47Control pressure [bar]Boiler pressure [bar]

Seite 4 - Important Notes

12Design PA 46, PA 47Fig. 3WVUTS3QPRNLOMKJIH1ACDBFEG

Seite 5

13Design MPA 46, MPA 47Fig. 4WCDBFEGYVXTS3QPRNLOMKJIH42Z

Seite 6 - Explanatory Notes

14KeyA Locking lever B Mounting bracket C Check holeD Valve plug E Name plate F Gasket D 38 x 44 (DN 2032), D 52 x 60 (DN 4050) G Sealing plug H Val

Seite 7 -  continued 

15PA 46, PA 47, MPA 46, MPA 47InstallationThe intermittent valve for removing boiler sludge can be installed in horizontal or vertical pipes. The ha

Seite 8 - Technical Data

16Heat treatment of weldsA subsequent heat treatment of the welds is not required.1. Observe position of installation. The hand lever 1 or the hand l

Seite 9

17OperationDuration and frequency of intermittent boiler blowdownWhen the GESTRA intermittent valve opens, a localized lowpressure area forms around

Seite 10 - Technical Data  continued 

18Replacing stuffing box PA 46, PA 47 1. Undo retaining piece 3 for forkhead T and pull out hand lever 1. Fig. 3 2. Unscrew hexagonhead cap screws W

Seite 11

19Replacing stuffing box, valve seat and valve plug PA 46, PA 47 1. Undo retaining piece for forkhead T and pull out hand lever 1. Fig. 3 2. Unscrew

Seite 12

2ContentsImportant NotesUsage for the intended purpose ...

Seite 13

20Maintenance  continued Replacing stuffing box MPA 46, MPA 47 1. Detach pressure line for the control fluid of the diaphragm actuator from the scre

Seite 14 - 8") for control fluid

21Maintenance  continued Replacing stuffing box, valve seat and valve plug MPA 46, MPA 47 1. Detach pressure line for the control fluid of the diaph

Seite 15 - Installation

22WINIX® 5000 is a registered trademark of WINIX GmbH, NorderstedtMaintenance  continued If fluid leaks out of the control hole C, retighten the st

Seite 16 - Commissioning

23TorquesAll torques indicated in the table are based at a room temperature of 20 °C.Maintenance  continued Tools Spanner A. F. 13 mm, DIN 3113,

Seite 17 - Maintenance

24Fig. 5Maintenance  continued Single parts of stuffing box, valve plug, valve seatFig. 6NMLKLJHD

Seite 18 - Maintenance  continued 

25Fig. 7Maintenance  continued Mounting/removing valve seatFig. 8

Seite 19

26Maintenance  continued Mounting/removing control membraneFig. 967895

Seite 20

27Key5 Hexagonhead bolt M8 with hexagon nut M8 6 Upper part of the diaphragm actuator 7 Control membrane8 Lower part of the diaphragm actuator with c

Seite 21

28TorquesRetrofitting  continued All torques indicated in the table are based at a room temperature of 20 °C.Mounting the forkhead (hand lever for e

Seite 22

29Spare PartsSpare parts listItem DesignationStock code Stock codePA 46, PA 47 MPA 46, MPA 47J KL MN FInternal parts of stuffing box, DN 20 to DN 50:Ba

Seite 23 -  continued 

3MaintenanceDanger ...

Seite 24

30DecommissioningDangerRisk of severe burns and scalds to the whole body!Before loosening flanged connections, stuffing box unions or sealing plugs make

Seite 25

31We hereby declare that the pressure equipment PA 46, PA 47, MPA 46 and MPA 47 conform to the following European Directives: Pressure Equipment Dir

Seite 26

32www.gestra.de81844700/1205cm · © 2004 GESTRA AG · Bremen · Printed in GermanyGESTRA Agencies all over the world:Great BritainFlowserve Flow Control

Seite 27

4Important NotesSafety NoteThe equipment must only be installed and commissioned by qualified and competent staff.Retrofitting and maintenance work must

Seite 28 - Retrofitting  continued 

5Classification pursuant to Article 9 of the Pressure Equipment Directive (PED) 97/23/ECClassification pursuant to Annex 1 of ATEX Directive 94/9/ECImpo

Seite 29 - Item Designation

6Explanatory NotesScope of supplyPA 46 1 Intermittent valve for removing boiler sludge PA 461 Hand lever1 Installation manualPA 47 1 Intermittent valv

Seite 30 - Parts for retrofitting

7Explanatory Notes  continued DescriptionIntermittent valves for manual or automatic and programmecontrolled removing of boiler sludge from land

Seite 31 - Head of the Design Dept

8Technical Data Pressure Ratings (M)PA 46 EN – PN 40 Class 150, 300 (M)PA 47 EN – PN 63 Class 400 Materials Designation DIN EN DIN ASTM Body *) PA...

Seite 32 - GESTRA AG

9Name plate / MarkingAccording to EN 19 the name plate and the housing indicate the valve type and design: Type designation PA 46, PA 47: Design

Verwandte Modelle: PA47 | MPA46 | MPA47 |