2 TRANSPORT AND STORAGE
2.1 Consignment receipt and unpacking
Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no
damage in transportation. Any shortage and/or
damage must be reported immediately to Flowserve
Pump Division and must be received in writing within
ten days of receipt of the equipment. Later claims
cannot be accepted.
Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to pallet,
box, or equipment.
Each product has a unique serial number. Check
that this number corresponds with the order. Always
quote this number in correspondence as well as
when ordering spare parts or further accessories.
2.2 Handling
Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction. The unit should be stored in a
level position with no strains applied.
2.3 Lifting
Pumps and motors often have
integral lifting lugs or eye bolts. These are intended
for use in only lifting the individual piece of
equipment.
Do not use eye bolts or cast-in lifting
lugs to lift pump, motor and baseplate assemblies.
Care must be taken to lift components
or assemblies above the center of gravity to prevent
the unit from flipping. This is especially true with
In-Line pumps.
Carefully sling ESP pumps so that
bearing lubrication lines (3840.1) will not be bent or
damaged when lifting.
It is advisable to raise the pump into the vertical
position before uncrating. If this isn't possible, pumps
over eight feet long must be supported at more than
one place when raising to the vertical position. Use a
support strap around the bottom column (1341.2)
and on the motor support (3160).
Pump Weights
(6 in.)
3x2x8
152 (335)
4.1 (9)
3x1.5x8
182 (400)
6.8 (15)
4x3x10
286 (630)
7.7 (17)
259 (570)
6.8 (15)
10x8x13 616 (1355)
16.4 (36)
16.4 (36)
Base pump lengths are 0.61m (2 ft.) for
Group 1 & Group 2 pumps and 0.91m (3 ft.) for Group
3 pumps.
On pumps equipped with grease lubricated
shaft bearings, (3020.1 and 3020.2) take care not to
flush the grease from the bearings.