CPXVC USER INSTRUCTIONS ENGLISH 26999930 03-11
Page 26 of 32 flowserve.com
FAULT SYMPTOM
Pump overhea ts and s eizes
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Bearings have short life
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Pump vibrates or is nois y
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Mechanical seal has shor t life
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Mechanical seal leaks excessively
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Pump requires excessive power
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Pump loses prime after starting
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Insufficient pressure developed
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Insufficient capacit y delivered
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
Pump does not deliver liq uid
⇓
⇓⇓
⇓
⇓
⇓⇓
⇓
PROBABLE CAUSES POSSIBLE REMEDIES
Incorrect type of mechanical seal for operating
conditions.
CONSULT FLOWSERVE.
Shaft running off centre because of worn bearings
or misalignment.
Check misalignment and correct if necessary. If
alignment satisfactory check bearings for excessive
wear.
Impeller out of balance resulting in vibration.
Abrasive solids in liquid pumped.
Internal misalignment of parts preventing seal ring
and seat from mating properly.
Check and CONSULT FLOWSERVE.
Mechanical seal was run dry.
Check mechanical seal condition and source of dry
running and repair.
Internal misalignment due to improper repairs
causing impeller to rub.
Check method of assembly, possible damage or
state of cleanliness during assembly.
Remedy or CONSULT FLOWSERVE, if necessary.
Excessive thrust caused by a mechanical failure
inside the pump.
Check wear condition of impeller, its clearances and
liquid passages.
Excessive grease in ball bearings. Check method of regreasing.
Lack of lubrication for bearings.
Check hours run since last change of lubricant, the
schedule and its basis.
Improper installation of bearings (damage during
assembly, incorrect assembly, wrong type of
bearing etc).
Check method of assembly, possible damage or
state of cleanliness during assembly and type of
bearing used. Remedy or CONSULT
FLOWSERVE, if necessary.
Damaged bearings due to contamination.
Check contamination source and replace damaged
bearings.
C. MOTOR ELECTRICAL PROBLEMS
Wrong direction of rotation. Reverse 2 phases at motor terminal box.
Motor running on 2 phases only. Check supply and fuses.
Motor running too slow. Check motor terminal box connections and voltage.