Flowserve Type R Bedienungsanleitung Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
R and RX SLURRY Pump USER INSTRUCTIONS ENGLISH 71569242 03-11 (E)
Page 47 of 56 flowserve.com
®
7 FAULTS; CAUSES AND REMEDIES
FAULT SYMPTOM
Pump overheats and seizes
Bearings have short life
Pump vibrates or is noisy
Mechanical seal has short life
Mechanical seal leaks excessively
Pump requires excessive power
Pump loses prime after starting
Insufficient pressure developed
Insufficient capacity delivered
Pump does not deliver liquid
PROBABLE CAUSES POSSIBLE REMEDIES
A. System troubles
Pump not primed.
Check complete filling. Vent and/or prime.
Pump or suction pipe not completely filled with
liquid.
Suction lift too high or level too low.
Check NPSHa>NPSHr, proper submergence,
losses at strainers/fittings.
Insufficient margin between suction pressure and
vapour pressure.
Excessive amount of air or gas in liquid. Check and purge pipes and system.
Air or vapour pocket in suction line. Check suction line design for vapour pockets.
Air leaks into suction line. Check suction pipe is airtight.
Air leaks into pump through mechanical seal,
sleeve joints, casing joint or pipe plugs.
Check and replace faulty parts.
CONSULT FLOWSERVE.
Foot valve too small. Investigate replacing the foot valve.
Foot valve partially clogged. Clean foot valve.
Inlet of suction pipe insufficiently submerged. Check out system design.
Speed too low. CONSULT FLOWSERVE.
Speed too high. CONSULT FLOWSERVE.
Total head of system higher than differential head
of pump.
Check system losses.
Remedy or CONSULT FLOWSERVE.
Total head of system lower than pump design
head.
Specific gravity of liquid different from design.
Check and CONSULT FLOWSERVE.
Viscosity of liquid differs from that for which
designed.
Operation at very low capacity. Measure value and check minimum permitted.
Remedy or CONSULT FLOWSERVE.
Operation at high capacity. Measure value and check maximum permitted.
Remedy or CONSULT FLOWSERVE.
B. Mechanical troubles
Misalignment due to pipe strain. Check the flange connections and eliminate strains
using elastic couplings or a method permitted.
Improperly designed foundation. Check setting of baseplate: tighten, adjust, grout
base as required.
Shaft bent. Check shaft runouts are within acceptable values.
CONSULT FLOWSERVE.
Seitenansicht 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 55 56

Kommentare zu diesen Handbüchern

Keine Kommentare