2.4 Shaft radial runout should be less than 0.0005 mm per mm (0.0005 inch
per inch) of shaft/sleeve diameter. See Figure 3. Turn the shaft through
360° and observe the range of indicator movement.
Check Axial Shaft Travel Figure 2
0.25 mm (0.010 inch) Maximum
Acceptable Axial Movement
Maximum Acceptable Radial
Runout 0.0005 mm per mm
(0.0005 inch per inch) of shaft
diameter
Check Radial Shaft Runout Figure 3
2 Recommendations
To ensure that your SLM-6200 Mechanical Seal will provide you with the longest possible
life, we recommend the following:
2.1 New radial and thrust bearings be installed in the pump.
2.2 The saddle ts of the bearing assembly should not be worn.
2.3 The axial end oat of the pump shaft must not exceed 0.25 mm (0.010 inch). See
Figure 2.
2.5 The shaft should deect no more than 0.30 mm (0.012 inch) at the seal chamber
face. See Figure 4.
Check Radial Shaft Deection Figure 4
Shaft should Deect no more than
0.30 mm (0.012 inch)
Seitenansicht 2