Tools
Open-end spanner (A.F. 22 mm or A.F. 27 mm)
Torque spanner (A. F. 22 mm or A. F. 27 mm)
Installation
TRG 5-53, TRG 5-54
1. Clean sealing surfaces.
2. Put gasket 13x 26 onto the sealing surface (choose the material of the gasket
according to the respective application).
3. Screw in temperature sensor and tighten with spanner when cold (torque 50 Nm).
TRG 5-55, TRG 5-56, TRG-5-57, TRG 5-58
1. Remove socket-weld end from temperature sensor.
2. Clean welding surfaces.
3. Arc-weld trap manually (welding process 111 complying to DIN EN 24063) or use
gas-welding process (welding process 3 complying to DIN EN 24063).
4. After welds have cooled down screw in temperature sensor and tighten with
spanner when cold.
Note
To install the temperature sensor in a pipe, weld knee bend to the pipe
such that the measuring tip is immersed in the fluid against the
direction of flow. Fig. 8, Fig. 9
Make sure that the measuring tip of the installed temperature sensor is
always in contact with the fluid. Fig. 3, Fig. 4
The temperature sensors must not be completely insulated. For more
details see examples of installation Fig. 6, Fig. 7