Pressure/Temperature Ratings*) CB 26, steel down to –10°C at nominal pressure
DN 50 200
Temperature [°C] 20 100 150 200 250 300 350 PN
Pressure DN 50200 [bar]
40 38 34 30 27 24 20 640
Pressure DN 250–300 [bar]
40 32 29 27 24 21 640
Technical Data
Explanatory Notes – continued –
Corrosion Resistance
If the unit is used for the intended purpose, its safety is not impaired by corrosion.
Sizing
The valve body must not be subjected to pulsating loads. Welds and flanges of the valve are designed
to withstand dynamic loading (bending and alternative stress).
The dimensional allowances for corrosion reflect the latest state of technology.
*) When used for its intended purpose.
Use CB... without springs for temperatures above 300 °C.
Pressure/Temperature Ratings*) CB 24 S, bronze down to –200 °C
at nominal pressure
DN 50300
Temperature [°C] 20 100 150 200 250 PN
Max. service
pressure
[bar] 16 16 16 14 13 6–16
*) When used for its intended purpose. With springs made of bronze up to max. 90 °C.
Pressure/Temperature Ratings*) CB 14, steel down to –10°C at nominal pressure
DN 50300
Temperature [°C] 20 40 60 80 PN
Max. service
pressure
[bar] 16 10 6 4 6–16
*) When used for its intended purpose.
Pressure/Temperature Ratings*) CB 26 A, stainless steel down to –10 °C
at nominal pressure
DN 50 300
Temperature [°C] 20 100 150 200 250 300 350 400 450 PN
Max. service
pressure
[bar] 40 38 35 32 30 29 28 27 26 640
*) When used for its intended purpose.
Use CB... without springs for temperatures above 300 °C.