FCD LMAIM5001-00 DDC-100 Master Station II Installation and Operation Manual 43
Flow Control Division
Limitorque Actuation Systems
04 —Read Input Registers
Reads the binary contents of the input registers in the field units. This function code will map the
following field unit registers 4 – 8 into a data table.
Read Input Registers Data Table
Master Field Unit Field Unit
Station Register Register Address MX-DDC UEC-3-DDC
30001 4 1 Torque Scaled Output* Average Torque Output
30002 5 1 Main Volts Analog Input
30003 6 1 Analog Input Analog Input
30004 7 1 Analog Input Analog Input
30005 8 1 Valve Position (Scaled) Valve Position (Scaled)
30006 4 2 Torque Scaled Output* Average Torque Output
30007 5 2 Main Volts Analog Input
30008 6 2 Analog Input Analog Input
30009 7 2 Analog Input Analog Input
30010 8 2 Valve Position (Scaled) Valve Position (Scaled)