InstallationInstructionsExperience In MotionMSS Seriesfor piloted and non-piloted models
10Note: Do not attempt to remove sealing face mismatch with the gland joint shoulder screws 414.1 fully tightened. Doing so may damage the
113.17 Mount the seal drive halves 2 around the shaft and loosely fasten them together with the shoulder screws 414 provided. Line up the pins in
TO REORDER REFER TOB/M #F.O.FIS130eng REV 03/10 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve C
2The MSS seal is a precision crafted split mechanical seal. While it has been designed for rugged industrial applications and ease of installation, it
3Notice: Cleanliness during installation is crucial to the satisfactory operation of the MSS seal.Caution: Installation of this seal requires
4 1.000 2.250 3.38 0.500 5.75 4.75 0.75 3.44 4.44 1.125 2.375 3.50 0.500 5.88 4.88 0.75 3.44 4.44 1.250 2.500
2 Installation of Piloted MSS2.1 Spray one end of one of the split stationary face seat gasket O-rings 13 with the adhesive accelerator provided.
2.4 Position the gland ring halves 11 around the shaft with the counter-bore facing the stationary face. Place the gland halves around the stationar
2.9 Install the white split backing ring 44 into the rotating face bore next to the O-ring. Install the two black elastomer backing rings 44.1. Be su
8 4.500 6.88 0.500 9.25 8.25 1.06 3.38 4.38 4.625 7.00 0.500 9.38 8.38 1.06 3.38 4.38 4.750 7.12 0.500 9.50 8.50 1.06 3.38 4.
3 Installation of Non-Piloted MSS3.1 Spray one end of the split gland gasket O-ring 18 with the adhesive accelerator provided. Apply one drop of
Kommentare zu diesen Handbüchern