Flowserve TRS 5-8 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
12
Use the two code switches at the rear of the TRS 5-8 to adjust the temperature limits,
Fig. 5.
Adjust MAX/MIN Temperature Limits
Example 1
Requested temperature limit τ
max
= 176°C. The 8-pole code switch shows values
between “2” and “256”. The basic temperature is 30 °C. Set the “2”, “16” and “128”
switches to the left using a small screwdriver. The sum of the three values gives a
temperature of 146 °C, plus the basic temperature of 30 °C. This corresponds to the
requested temperature limit τ
max
= 176°C.
Example 2
Requested temperature limit τ
max
= 446 °C. Set the “32”, “128” and “256” switches to
the left using a small screwdriver. The sum of the three values gives a temperature
of 416°C, plus the basic temperature of 30 °C. This corresponds to the requested
limit temperature τ
max
= 446 °C.
Example 3
Requested temperature limit τ
min
= 79°C. Set the “16” and “32” switches to the left
using a small screwdriver. The sum of the two values gives a temperature of 48°C,
plus the basic temperature of 30°C. This corresponds to a limit temperature τ
min
=
78°C. An adjustment of exactly 79 °C is not possible as temperatures can only be
adjusted in steps of 2°C.
Tool
Screwdriver for slotted screws, size 2.5, completely insulated according to
VDE 0680.
Switch on mains voltage. The green LED will be illuminated. Fig. 5
Commissioning
Check whether the TRS 5-8 has been wired to its associated system components
TRG 5-... according to the wiring diagram. Fig. 1, Fig. 6 or Fig. 7.
Check wiring
Apply mains voltage
3
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare