Seitenansicht 0
INSTALLATION,
OPERATING,
AND MAINTENANCE
INSTRUCTIONS
Experience In Motion
Chemiepac
955, 956, 958, 970, 971, 978
Experience In Motion
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Chemiepac

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONSExperience In MotionChemiepac955, 956, 958, 970, 971, 978Experience In Motion

Seite 2

regulations regarding safety measures and protective clothing with respect to this plant section must be observed and strictly adhered to. The operato

Seite 3

Installation, Operating and Maintenance Instructions Chemiepac Mechanical Sealof our products manufactured or procured by ourselves, and the replaceme

Seite 4

To find your local Flowserve representative and find out more about Flowserve Corporation, visit www.owserve.comFIS177eng Rev 07/05 Printed i

Seite 5

-2-To seal*Machine manufacturer : Machine type : End user : Plant : Works standard : Drawing number : see details based on the orderArticle iden

Seite 6

Installation, Operating and Maintenance Instructions Chemiepac Mechanical Seal1.0 BRIEF DESCRIPTION, FUNCTION1.1 Specifications for the operations desc

Seite 7

1.4 Function The MS is supplied with liquid from the product.There must always be liquid at the seal gap to generate a seal film. The seal film also exi

Seite 8

Installation, Operating and Maintenance Instructions Chemiepac Mechanical Seal! ! ! -5-2.3 Damage may cause leakage in liquid or gaseous form. The

Seite 9

! ! ! -6-5.0 PREPARING FOR INSTALLATION5.1 The MS may be installed when there are no visible signs of damage to the MS. This applies in particular

Seite 10

Installation, Operating and Maintenance Instructions Chemiepac Mechanical Seal6.0 INSTALLATION6.1 Observe the machine manufacturer’s specifications and

Seite 11

6.6 Should there be gas or air pockets in the sealing chamber, these can accumulate with the rotation at the outer diameter of the seal gap at machine

Seite 12 - flowserve.com

Installation, Operating and Maintenance Instructions Chemiepac Mechanical Sealcomponents must be monitored at all times by a device that shuts down th