Maintenance – continued –
1. Take heed of the danger note on page 5.
2. Cut off power supply to actuator
1.
3. Undo hexagon screws
7 and remove actuator and coupling 8.
4. Unscrew the hexagon nut
T and detach control lever U with the aid of a pulling device.
5. Undo stuffing box screws
A, remove stuffing box gland C, scale plate B, disk springs D and
spring sleeve
E.
6. Unscrew nozzle stem
R and pull is out of the valve body.
7. Unscrew locking screw
P and remove gasket Q.
8. Unscrew sealing plug
O and remove gasket N.
9. Use a brass drift punch d = 14.8 mm to force out the internals
F to J, Fig. 14
10. Clean and, if required, exchange valve body
K and internals.
11. Apply glue type “Loctite
®
620” to seat bushing J and put it in place. Insert stage bushing I.
12. Align wearing bushing
H in such a way that the groove is on the longitudinal axis of the locking
screw
P.
13. Screw in the locking screw
P together with gasket Q and tighten it with a torque of
5 Nm (DN 15 – 32) or 11 Nm (DN 40, 50) when cold.
14. Align and insert the guide sleeve
G in such a way that the groove on the longitudinal axis
is on the locking screw
P, Fig. 12.
15. Insert new wiper rings and packing rings
F as shown, Fig. 12.
16. Apply lubricant (type WINIX
®
2010) to the thread and sealing surface of the nozzle stem.
17. Insert nozzle stem
R and screw it into the guide sleeve G by two turns.
18. Insert spring sleeve
E and disk springs D in the shown sequence.
19. Put scale plate
B and stuffing box gland C in place and tighten stuffing box screws A slightly.
20. Screw out nozzle stem
R by half a turn and fasten stuffing box screws A with a torque of
7 Nm (DN 15 – 32) or 11 Nm (DN 40, 50).
21. Turn nozzle stem
R into the closed position, applying a torque of 7 Nm. Put control lever U in
place and align scale S with the scale plate B such that the diamond-shaped marker “0” is in the
middle of the scale plate.
Changing packing and internals of BAE 46, BAE 47
WINIX
®
2010 is a registered trademark of WINIX GmbH, Norderstedt
LOCTITE
®
is a registered trademark of HENKEL KgaA, Düsseldorf
Changing packing and internals of BA 46, BA 47 – continued –
15. Insert nozzle stem R and screw it into the guide sleeve G by two turns.
16. Insert spring sleeve
E and disk springs D in the shown sequence.
17. Put scale plate
B and stuffing box gland C in place and tighten stuffing box screws A slightly.
18. Screw out nozzle stem
R by half a turn and fasten stuffing box screws A with a torque of
7 Nm (DN 15 – 32) or 11 Nm (DN 40, 50).
19. Turn nozzle stem
R into the closed position, applying a torque of 7 Nm. Put control lever U in
place and align scale
S with the scale plate B such that the diamond-shaped marker “0” is in the
middle of the scale plate.
20. Screw hexagon nut
T onto the threaded part of the nozzle stem R and tighten with a torque of
20 Nm while holding the control lever.
21. Screw sealing plug
O together with gasket N into the valve body and tighten with a torque of
130 Nm or screw in the sample valve with the gasket according to the instructions given by the
manufacturer.