14
Maintenance – continued –
Torques for tightening
All torques refer to a room temperature of 20 °C.
1. Observe the danger note on page 4!
2. Unscrew body screws
A and take the cover E off the body I, Fig. 2
3. Unscrew hand purging knob
B.
4. Unscrew valve insert
F.
5. Unscrew sealing plug
L and strainer J.
6. Clean strainer, sealing plug and gasket surfaces.
7. Clean seating surfaces of body and cover.
8. Apply heat-resistant lubricant to all threads, seating surfaces of the valve insert and of the cover
(e. g. WINIX
®
2150).
9. Replace gasket
H only if there are visual signs of damage.
10. Replace gasket
K if there are visual signs of damage.
11. Mount new hand purging knob
F and tighten with a torque of 40 Nm.
12. Mount new valve insert
B and tighten with a torque of 90 Nm.
13. Put cover on valve body. Tighten body screws evenly with
25 Nm.
14. Mount sealing plug
L together with strainer J and tighten with 120 Nm.
Replace hand purging knob and valve insert
Tools
■ Spanner 16 mm A.F., DIN 3113, Form B
■ Spanner 19 mm A.F., DIN 3113, Form B
■ Spanner 22 mm A.F., DIN 3113, Form B
■ Torque spanner 20-120 Nm, DIN ISO 6789
WINIX
®
2150 is a registered trademark of WINIX GmbH, Norderstedt
Item
Designation Torque [Nm]
F
Valve insert 090
B
Hand purging knob 040
A
Body screws 025
L
Sealing plug 120