LME0009-1 (Auto-39) 04/03
©
2003, Flowserve Corporation, Printed in USA
3-Position Control/Dribble Control
SR Limit Switch Method
Flowserve Corporation 1350 N. Mountain Springs Parkway Phone: 801 489 8611
Flow Control Division Springville, Utah 84663-3004 Facsimile: 801 489 2228
www.flowserve.com
Automax Valve Automation Systems
Installation, Operation and Maintenance Instructions
Page 4 of 4
Typical Actuator Specifications
Action Reversible
Supply Voltages AC: +/ 115VAC (1 Ph)
10% 230VAC (1 Ph)
50/60Hz 24VAC (1 Ph)
DC: 12VDC
24VDC
Temperature Rating -20°F (-28°C) to 160°F (70°C)
Enclosure Ratings / Device Testing CSA Enclosure 4
NEMA 4, 4X
89/336/EEC Directive for CE Marking
Range of Operation 0° to 180°
AC Motor Thermal Protection Automatically resetting
Motor Types AC: Permanent Split Capacitor
DC: Brush
Travel and Aux. Switches SPDT, Form C 15 amp 125 1/2 HP 10 amp
250VAC, 1/2 amp 125 VDC
Conduit Connections (1) 3/4-14 NPT
Corrosion Protection Enclosure: Zytel engineered resin
Cover Screws: Stainless Steel
Output Shaft: Dacromet Coating
Terminal Strip Hookup 300V, 30A, 12-26 AWG
Lubrication Permanently lubricated
Gear Train Heat treated alloy steel, rated to stall torque
Note: The above ratings may change depending on model configurations and options provided.
Products may differ as the result of the Company policy of continuous product improvement.
Actuator Model
CPL1 CPL2
Cycle Times
Sec/90°
56
34
34
87
100 225 Torque (in-lbs)
11 25 Torque (Nm)
4 5 Weights Lbs (kg.)
CPL1 CPL2 CPL1 CPL2
Std 115 50 0.3 0.5 .04 0.5
B 12 100 1 1.6 * *
C 24 100 0.5 0.8 * *
D 230 50 0.11 0.18 0.12 0.2
Opt.
Motor
Desig.
Motor
Voltage
Duty
Cycle
(%)
Run Current
(amp)
Locked Rotor
(amp)
1. Cycle times are approximate under no load conditions and may vary slightly under actual
operating conditions.
2. Duty cycles are rated at 70°F. The duty rates may be less under loaded conditions.
3. Do not lock up DC motors.