Installation
Instructions
Experience In Motion
GCX Series
Single bellows cartridge seal incorporating graphite secondary seals
to meet the demands of the chemical processing industry
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Instructions

InstallationInstructionsExperience In MotionGCX SeriesSingle bellows cartridge seal incorporating graphite secondary seals to meet the demands of the

Seite 2 - 1 Equipment Check

103 Single Seal Piping and Operational Recommendations3.1 Install an adequate seal ush system. The GCX requires a clean cool environment for m

Seite 3 - Figure 1

115 RepairThis product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by F

Seite 4 - Figure 2

TO REORDER REFER TOB/M #F.O.FIS172eng REV 02/12 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve C

Seite 5 - Figure 3

2DescriptionThe GCX seal is a cartridge mounted mechanical seal, designed for ease of installation and reliable operation. No seal setting dimensions

Seite 6 - 2 GCX Installation

31.5 Check equipment dimensions to ensure that they are within the specications shown in Figures 1, 2, and 3. Critical dimensions from Figure 2 inc

Seite 7 - Figure 6

4GCX Dimensional Data in millimeters (inches) - Standard Bore Figure 2GKJØ EØ AShaft Size& Seal SizeØ CØ DF A C D E F G J K L M Shaft &

Seite 8 - Figure 7

5GCX Dimensional Data in millimeters (inches) - Enlarged Bore Figure 3GKJØ EØ AShaft Size& Seal SizeØ CØ DF A C D E F G J K L M Shaft &

Seite 9 - Figure 9

62 GCX InstallationNote: The GCX seal is shipped with the sleeve and gland graphite gaskets uninstalled. These parts must be assembled onto the seal

Seite 10

72.7 Install the complete GCX cartridge assembly onto the shaft or sleeve with the setting devices near the bearing housing. See Figure 5.2.8 Instal

Seite 11 - 5 Repair

82.9 Position the GCX with the gland tight against the seal chamber face. If equipment conditions allow, position gland with the outlet port or plugg

Seite 12 - flowserve.com

92.12 Tighten the set screws. See Figure 8. Suggested minimum torque values for set screws are as follows: Figure 8 Shaft Size Set Screw Size