6.3.3 Tightenjamnut 9-1ontheimpellersideoftheclamp.
6.4 Fillthepumpwithprocessuidorwaterensuringairispurged
from pump to check for static leaks. Repair any leaks before
start-up.
6.5 Startthepumpandcloselymonitorsealleakageforapproxi-
matelytwohours.Sealleakagecanbeinitiatedbydimensional
changes in the pump after start-up that may reduce seal com-
pression. Example:
Axialshaftmovementduetobearingclearancesandthermal
growth.Ifvisibleleakageisobservedshortlyafterstart-up,
adjustthesealoneatandwait10to15minutesforthefull
effect of the change. If necessary, repeat the procedure no more
than3times(6attotalor1completeturnofthenut).Iftheleak
hasnotbeenreduced,itisastaticleakorthesealfaceshave
beendamaged.Furtheradjustmentmaydamagetheseal.
Fortechnicalassistanceorinformationpertainingtoyourparticular
application,contactyournearestauthorizedFlowservedistributor.
10
6.3.2 Tighten9adjustingnutthenumberofatsinthetable
below.(1at=1/6turnofthenut)
StudSize Compression(inches) Compression
(inches) 0.040/0.050 PerFlatinches(mm)
3/8-16UNC 4Flats 0.010(0.254)
1/2-13UNC 4Flats 0.013(0.330)
5/8-11UNC 3Flats 0.015(0.381)
3/4-10UNC 3Flats 0.017(0.432)
1-8 UNC 2Flats 0.021(0.533)
StudSize Compression(Inches) Compression
(metric) 0.040/0.050 PerFlatmm(inches)
M10x1.5 4Flats 0.254(0.010)
M12x1.75 4Flats 0.279(0.011)
M16x2.0 3Flats 0.330(0.013)
M20x2.5 3Flats 0.406(0.016)
M24x3.0 2Flats 0.508(0.020)