4.2 For dual pressurized seal (double seal) operation, supply a clean
compatible barrier uid to the inlet port at a pressure at least
170 kPa (25 psi) above the seal chamber pressure. See Figure 9.
The pressure of the barrier uid must not exceed the recommended
maximum pressure. Flowserve can supply information on barrier
uid ow requirements based on seal size, product temperature,
barrier uid characteristics, and shaft speed.
4.3 For dual unpressurized (tandem seal) operation, supply a clean
compatible buffer uid to the inlet port at a pressure below the seal
chamber pressure. See Figure 10. The pressure in the seal
chamber must not exceed the recommended maximum pressure.
Flowserve can supply information on buffer uid ow requirements
based on seal size, product temperature, buffer uid characteristics,
and shaft speed.
Double ISC with Supply Tank Figure 9
Bypass
Flush to
Gland
Flush Port
Supply Tank
Assembly with
Cooling Coils
1.2 m (4 feet)
maximum
Pressure
Source
0.45 - 0.6 m
(1.5 - 2 feet)
minimum
Orifice
Option