Seal Chamber Requirements Figure 1
1 Equipment Check
1.1 Follow plant safety regulations:
•lockoutmotorandvalves.
•weardesignatedpersonalsafetyequipment.
•relieveanypressureinsystem.
•consultplantMSDSlesforhazardousmaterialregulations.
1.2 Disassemble equipmenttoallowaccesstosealinstallationarea.
1.3 Remove all burrsandsharpedgesfromtheshaftorsleeve
includingsharpedgesofkeywaysandthreads.Replacewornshaft
orsleeve.Makesurethesealhousingboreandfacearecleanand
freeofburrs.
1.4 Check requirementsforshaft,sleeve,andsealhousing.
SeeFigure1.
1.5 Check assembly drawing includedwiththesealforspecic
sealdesign,materialsofconstruction,dimensions,andpiping
connections.
To first obstruction
Face of seal housing to be square to the axis
of the shaft to within 0.013 mm per millimeter
(0.0005 inches) of seal chamber bore FIM and
have a 1.6
μm (63 μinch) R finish or better
a
Gland pilot can be at either of these
register locations, concentric to within
0.13 mm (0.005 inch) FIM of shaft or sleeve OD
Seal housing bore to have 3.2 μm
(125 μinch) R finish or better
Sleeve or shaft finish to be
0.8 μm (32 μinch) R or better
a
a
Shaft or sleeve OD
+0.000 mm (+0.000 inch)
-0.050 mm (-0.002 inch) ANSI
+0.000 mm (+0.000 inch) API 610/682
-0.025 mm (- 0.001 inch) DIN/ISO
• Bearings must be in good condition
• Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) FIM
• Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) FIM
• Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) FIM