4
2.5 Lightly lubricate the O-ring or Duraex stationary seat
gaskets.WhereastationaryfacehasanO-ringmountingonthe
shoulder,itisusuallybettertonestthisO-ringintheglandcavity
beforeinstallingtheface.Otherstationaryfacemountingscanbe
assembledonthestationaryfaceshoulder.
2.6 Press the stationary face into the gland withthesealingface
orientatedtowardtheoutboardsideofthegland,facingtherotating
sealface.Usehandpressureonly.
2.7 Position the glandovertheshaftorsleevewiththestationary
sealingfaceorientatedtowardtherotatingfacesealingface.
Placetheglandasclosetotherotatingassemblyaspossible.
Donotbumpthestationaryfaceagainsttheshaftasitmaychip,
crack,orbreak.
2.8 Install the pump back-plate and assemble the pump. Position
the gland sotheglandorstationaryfacepilotisproperlyengaged
and tighten the gland stud nutsupevenly,crossstaggeringthe
adjustmentofthenuts.Theglandnutsshouldbetorquedtoa
maximumof13N-m(10ft-lbs).Excessiveglandnutpressurecan
resultindistortionoftheinsert.Adjust the bearings, coupling,
and impellersothattheshaftisinitsoperatingaxialposition.Any
subsequentaxialadjustmentoftheshaftrequiresresettingofthe
sealrotaryunit.
2.9 Wipe the seal faces cleanwithalcohol.Sealfacesshouldnotbe
lubricatedbutshouldbeleftcleananddry.
2.10 Position the rotating assembly sothatthesealfacesarein
contactandpositionthespringholdersothatthespringgap(or
bellowsrotaryunitlength)isthatgivenontheassemblydrawing.
Thespringgapdimensionisalsostampedonthespringholder.
Tighten the set screwsrmlyandevenly.
2.11 See paragraph 4, Operational Recommendations beforestarting
pump.