
6
Recommended Piping for Tandem Designs Figure3
API Plan 52
1. Solenoidvalveindrainisnormallyopenallowingprimarysealweepageto
ventthroughorice.
2. Ifprimarysealleakagebecomesexcessive,thepressureswitchinthe
secondarysealthermalconvectionloopwillactivatealarmandclose
solenoidvalveinthedrainline.
3. Bypasslinearoundsolenoidvalveisnormallyclosedbutisusedtobleed
systempressure.
Pressure Alarm
and Switch
Fill Connection
Supply Tank Assembly
API Plan 11
Bypass Line From
Pump Discharge
Orifice
.031" (.8mm)
Solenoid Valve
(normally open)
1 foot
(300 mm)
minimum
Bypass Valve
(normally closed)
To Recovery
Orifice
Option
Primary
Seal
Secondary
Seal
Kommentare zu diesen Handbüchern