PLEUGER STANDARD USER INSTRUCTIONS ENGLISH 71569293 01-13
Page 23 of 40 flowserve.com
The connection apertures for filling the motors vary
according to the motor type and model. Table 6-5
shows the filling aids which are required for filling or
topping up motors.
Table 6-5
Motor type
Suction
shroud
Filling
valve
Screw plug
Filling
accessory
* Filling nipple
Thread size -
hose diameter
M6
MX6
without
without
screw plug
funnel
with
3
/
8
in
* M10 - Ø15/19
pump
M8
MX8
without
without
screw plug
funnel
with
3
/
8
in
* M10 - Ø15/19
pump
MI10
MIX10
without
without
screw plug
funnel
with
3
/
8
in.
* M10 - Ø15/19
pump
VNI12
¾ in.
* M16 - Ø15/19
pump
VNI14
MI16
MI19
VNI22
MI26
VNI30
6.5.4 Filling pump
The filling pump is only suitable for filling motors that
are equipped with a filling valve [B6514] in the bottom
bearing or thrust bearing housing.
A filling valve [B6514] can be fitted in place of a
screw plug [6780], however the valve cannot be
screwed out again after the motor has been filled; it
must remain fitted. Replacing the screw plug does
not affect the functioning of the motor.
6.5.5 Sealing cap
The sealing cap [0236] must only be fitted for
transportation and storage.
The sealing cap [0236) must always
be removed when the motor is put into service.
6.5.6 Filling liquid
If a motor has to be filled or topped up with a mixture
of water and antifreeze, this must be prepared in a
clean container before filling the motor.
6.5.7 Header tank (optional)
If a header tank is installed it is recommended that it
is fitted with a float switch for automatic monitoring of
the liquid. This ensures that the motor is always full.
The header tank must be not more than 5 m (16.4 ft),
corresponding to 0.5 bar (7.25 psi), above the lowest
level of the pumped liquid, or the motor, to ensure
sealing of the motor. If a greater height cannot be
avoided, the manufacturer must be consulted.
6.5.7.1 Pipes
When installing a header tank, pipes with a nominal
size of at least 13 mm (½ in.) must be used between
tank and motor for venting and filling the motor.
To ensure the motor is properly filled, the installation
of a drain valve in the return pipe below the tank
bottom is recommended. This valve must remain
open during filling and topping up until the liquid
escaping from it is free of bubbles.
The drain valve must never be fitted
so that it can shut off the return pipe.
6.5.8 Vent valves
Vent valves are available with different pressure
ratings. The appropriate valve is selected according
to the purpose for which the submersible motors are
to be used. So that filling with liquid does not have to
take place against the opening pressure of the vent
valve, it can be screwed out for the duration of filling if
the installation position allows this.
It is essential that the vent valve is
screwed in again after filling.
6.5.9 Accessory pack “Z”
For submersible motors installed horizontally, and in
some cases vertically, the vent valves and screw
plugs must be exchanged or replaced on site. The
parts required for this are supplied in accessory pack
“Z”, as shown in table 6-6, with the respective motor.
Relevant instructions are given in the filling details for
the particular motor type and for the specific
application.
Table 6-6: Accessory pack “Z”
Item no.
Description
Quantity
B6523
Vent valve
1
6780
Screw plug
1
4510
Sealing ring
3
6.6 Filling instructions
The procedures for filling and topping up submersible
motors described below depend on the method of
installation and the type of motor used. As a rule it is
not possible to use all installation methods for all
motor types, and for this reason the following table
shows which installation methods are used as
standard for the different motors. For special cases
not mentioned here, the manufacturer must be
consulted.
The relevant section for motor filling must be taken from
the data sheet belonging to the corresponding unit.