PLEUGER STANDARD USER INSTRUCTIONS ENGLISH 71569293 01-13
Page 32 of 40 flowserve.com
7.3 Switching off the unit
To minimize water hammer the control valve (see
item 8, figure 3-1) must be closed before the unit will
be switched off. After the valve has been closed the
unit must be switched off within 2 to 3 minutes.
8 MAINTENANCE
Submersible pump units normally run without needing
maintenance.
If a pump unit should stand idle for a lengthy period of
time, perform a 10 minute test run every month, so
that potential malfunctions can be recognized in time.
The pump unit must be completely
submersed in pumping medium for this test run.
8.1 General information
As the units are normally used at very great depths, it
is recommended that the following checks are
performed and recorded at regular intervals, in order
to recognize malfunctions in time:
Current consumption
Head
Flow
System voltage
Operating hours
Insulation test
Temperature (only if temperature sensors
PT100 [RTD] exist)
Current consumption of the motor is the most
important test for monitoring the unit.
For finding problems, their cause and elimination, see
section 9, Faults; causes and remedies.
8.2 Pump units
The pump unit can be operated without maintenance,
insofar as there are no irregularities in operation or
pumping, caused by sand or a corrosive pumping
medium, that make premature removal necessary.
Fluctuating and or rapidly increasing current
consumption indicate mechanical problems in the
pump or motor.
Strong oscillation of the pressure, and at the same
time of the ammeter, can be caused by irregular
water inflow.
8.3 Measuring insulation
8.3.1 Motor including power supply cable
Before initial starting, or after long storage or idle
time, the insulation resistance of the drive must be
measured.
During and after measurement, the
conductor ends of the motor power cable and or
the connection terminals may carry dangerous
voltage (up to the test voltage) and must not be
touched. Before measuring, ensure that there is
no line voltage.
To measure the insulation of the system, disconnect
all leads of the power supply cable.
All leads must be carefully cleaned to remove dirt or
corrosion. Follow the instructions given with the
insulation measurement instrument.
Insulation measurement is always performed with a
measuring-circuit voltage of 500 volts. The value
must be read for the duration of a minute.
The motor windings or power cable, charged up to the
measuring-circuit voltage, must be discharged after
measurement using the insulation-measuring device.
The minimum insulation resistance and critical
insulation resistance limits for measurements at a
winding temperature of 20 °C (77 °F) are as follows:
New motors
Over 150 M
Minimum insulation value of new motors
with power supply cable
5.0 M
Critical insulation value after longer
operation time
0.5 M
If the insulation value is near the minimum, causes
could be increased air humidity and or dirty, moist
conductor ends or a winding temperature higher than
20 °C (77 °F).
A relatively low insulation resistance does not
definitely show that the motor will break down due to
insulation problems.
However the insulation must be inspected, if after
measurements over a longer period, an extreme drop
in the insulation resistance occurs within a short time.
If the insulation resistance falls below the minimum
value, the cause must be determined or the faulty
part (power cable, line connection or windings)
identified and the insulation weakness removed.