FAULT SYMPTOM
Motor protection triggered

Pump does not start

Motor overheats

Unit runs but does not pump

Unit vibrates or is noisy

Motor loses filling liquid

Pump requires excessive power

Pump does not draw in water at start

Insufficient pressure developed

Insufficient capacity developed

PROBABLE CAUSES
POSSIBLE REMEDIES
A. System problems




Abrasive solids in liquid pumped.
Check and consult Flowserve.







Internal misalignment due to improper repairs
causing impeller to rub.
Check method of assembly, possible damage
or state of cleanliness during assembly.




Excessive thrust caused by a mechanical
failure inside the pump.
Check wear condition of impeller, its
clearances and liquid passages.




Improper installation of bearings.
Check method of assembly, possible damage
or state of cleanliness during assembly and
type of bearing used.




Damaged bearings due to contamination.
Check contamination source and replace
damaged bearings.



Slide valve not fully open.
Open slide valve.




Pressure pipe clogged. Foreign body in the
pipe line.
Clean pipe work.





Pump blocked by impurities inside the pump.
Disassemble pump section and clean.







Pump or motor sluggish.
Check smooth running of motor/pump.




Well filter clogged up.
Remove unit and regenerate well.


Coupling between pump and motor faulty.
Remove unit and repair.






Suction strainer clogged up.
Remove unit and clean suction strainer.
C. Electrical problems




Wrong direction of rotation of motor.
Reverse two phases at motor terminal box.


Motor circuit breaker incorrectly adjusted.
Readjust motor circuit breaker according to
data card or rating plate.







Motor running too slow. Under voltage or
wrong frequency.
Check if system voltage and frequency agree
with data sheet.






Phase failure.
Examine power cable for damage. Check
fuses.






Blown fuses.
Replace fuses.



Damaged power cables.
Replace power cables.