PLEUGER STANDARD USER INSTRUCTIONS ENGLISH 71569293 01-13
Page 8 of 40 flowserve.com
Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.
Locking system for mechanical seals must be
monitored for leaks of the delivery medium and the
locking medium.
Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be monitored.
If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device.
1.6.4.7 Maintenance to avoid the hazard
CORRECT MAINTENANCE IS REQUIRED TO
AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION
The responsibility for compliance with maintenance
instructions is with the plant operator.
To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.
It is recommended that a maintenance plan and
schedule is adopted. (See section 8, Maintenance.)
1.7 Nameplate and safety labels
1.7.1 Nameplate
For details of nameplate, see the Declaration of
Conformity, or separate documentation included with
these User Instructions.
1.7.2 Safety labels
Oil lubricated units only:
1.8 Specific machine performance
1.8.1 General
For performance parameters see section 1.5, Duty
conditions. Where performance data has been supplied
separately to the purchaser these should be obtained
and retained with these User Instructions if required.
1.8.2 Ecodesign
EU regulation 547/2012 of the Directive
2009/125/EC, for the minimum efficiency of defined
classes of water pumps requires that products must
show their Minimum Efficiency Index (MEI) value.
The EU benchmark MEI 0.70. Also product
information must be available to users.
Performance curves will have been provided with the
quotation or order or are available at flowserve.com.
The efficiency of a pump with trimmed impeller is
usually lower than that of a pump with the full impeller
diameter. Trimming of the impeller will adapt the
pump to a fixed duty point, leading to reduced energy
consumption. The minimum efficiency index (MEI) is
based on the full impeller diameter.
The operation of this water pump with variable duty
points may be more efficient and economic when
controlled by, for example, by the use of a variable
speed drive that matches the pump duty to the system.