overstress these components, e.g. the max permitted tightening
torque must not be exceeded.
6
.8 Assemble the equipment per manufacturer specifications. Avoid
pipe strain. Align the coupling per manufacturer specifications.
6
.9 With the impeller, shaft, coupling and bearings in their final oper-
a
ting position, tighten the drive collar set screws. See Figure 4.
Recommended ISC2 seal minimum set screw
torque by size range:
Seal inch
1.000 - 2.500 2.625 - 2.750 2.875 - 8.000 2.875 - 8.000
Size (mm) (25 - 60) (67 - 70) (75 - 203) (75 - 203)
Gland Size All All Standard Bore Enlarged Bore
Torque
40 in-lbs 120 in-lbs 150 in-lbs 240 in-lbs
(4.5 N-m) (13.5 N-m) (16.9 N-m) (27.1 N-m)
Inaccurate tightening of these screws can lead to unsafe situa-
tion as mechanical seal may move out of the seal chamber when
pressure is applied.
Figure 5